Pass-through charging and UPS mode explained: leaving the battery plugged in so the outage finds it full

What pass-through charging is, how a power station's UPS mode differs from a real UPS, the switchover times makers state, and how to set one up.

Pass-through charging and UPS mode explained: leaving the battery plugged in so the outage finds it full Sizing for this? Read Battery Backup for a Refrigerator: Real Runtimes

Every appliance page on this site says the same thing about the units it ranks: plug the battery into the wall, plug the refrigerator into the battery, and leave it. That is pass-through charging with a UPS mode, and it is the difference between a battery that protects a refrigerator with nobody home and one that protects it only if you are there to carry it downstairs. Here is what the mode is, what it is not, and the numbers the makers state for it.

What pass-through charging is

Plugged into the wall, a power station in pass-through mode feeds its outlets from the grid and keeps its battery at full charge. When the grid fails, its inverter takes over the outlets from the battery. When the grid returns, it hands back and recharges. The load sees a single brief gap at each transition, measured in milliseconds, and that gap is the specification that matters.

What the makers state for the gap

UnitSwitchover statedPage
EcoFlow DELTA 3, DELTA 3 Plus, DELTA 3 Max, RIVER 3 Plusunder 10 ms1 kWh, 2 kWh, CPAP
Anker SOLIX C1000 Gen 2, C2000 Gen 2, C30010 ms1 kWh, 2 kWh, CPAP
EcoFlow DELTA 2 Maxunder 20 ms2 kWh
Anker SOLIX F3800, F3000under 20 msexpandable
Bluetti AC18020 msrefrigerator
Jackery Explorer 1000 v2under 20 ms1 kWh

Figures from the makers’ pages on the dates printed on each card. For a refrigerator, a sump pump or a freezer, any of them is fine: a compressor does not notice 20 ms. For a desktop computer or a router, 10 ms is inside what nearly every power supply rides through and 20 ms usually is. For anything life-critical the CPAP page’s note applies: ask the equipment’s maker what gap it tolerates, and treat the answer as the specification.

What it is not

A true online UPS, the kind a data centre uses, has no switchover at all: the load runs from the inverter continuously and the grid only charges the battery. Power stations are line-interactive at best. The makers’ own language is careful about this, “UPS mode” or “EPS,” and the honest reading is: fast enough for almost everything in a house, not a guarantee of zero interruption. Two other differences: a power station’s outlets are the ones on its face, not the whole circuit, so it protects what is plugged into it; and it does not condition the grid’s voltage the way a good UPS does.

Setting it up

  1. Plug the unit into the wall outlet nearest the appliance, on its own circuit if possible.
  2. Enable the UPS or pass-through setting in the unit’s app if it has one; on most units it is on by default when plugged in.
  3. Plug the appliance into the unit’s AC outlet. For a refrigerator, that is all; the battery is now a buffer between the wall and the compressor.
  4. Check the unit’s display or app once: it should show grid input and full charge.
  5. Once a season, unplug the wall side for a minute and watch the appliance keep running. A rehearsal is worth more than a spec sheet.

The two trade-offs

Holding at 100%. A battery kept full ages slightly faster than one at 50%. LiFePO4 tolerates it far better than the NMC cells of a few years ago, and every maker designs its UPS mode around it; EcoFlow’s guidance to store between 30 and 85%, in the lifespan guide, is for a unit on a shelf, not one on float. For a backup battery, full when the outage arrives is worth the trade.

Heat and fan noise. Passing a refrigerator’s load through the unit all day warms the electronics, and some units run a fan. Keep it out of a closed cabinet and off carpet, and for a bedroom CPAP prefer the units the CPAP page notes as quiet.

What it changes about sizing

Nothing about the watt-hours, everything about the starting point. A unit that lived on a shelf arrives at the outage with whatever the shelf left it; a unit in UPS mode arrives full. When you size from the runtime tables or the calculator, the figures assume a full battery, and this is how you get one.

Frequently asked questions

What is pass-through charging?

Running loads from a power station's outlets while it is itself plugged into the wall. Grid power feeds the loads and keeps the battery topped up; when the grid drops, the battery takes over. Every unit ranked on this site supports it.

Can a power station replace a UPS for a computer?

For most equipment, yes, if its switchover is fast enough: EcoFlow and Anker state 10 ms or less on their current units, which is inside what most power supplies ride through. It is not an online UPS, which has no switchover at all; for a server or medical equipment, ask the equipment's maker what gap it tolerates.

Does leaving a power station plugged in all the time hurt the battery?

Holding at 100% is the trade. LiFePO4 tolerates it far better than older chemistries, and every maker's UPS mode is designed around it; EcoFlow's storage guidance of 30 to 85% is for a unit sitting unplugged, not one on float. The upside is that the outage finds the battery full.

Which is better for a refrigerator, UPS mode or plugging it in when the power fails?

UPS mode. The refrigerator never sees the outage, nobody has to be home, and the battery starts full. Plugging in after the fact costs whatever the shelf took and the time it takes to notice the lights are out.

Disclosure: Usable kWh is reader-supported. We are a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com. When you buy through links on our site, we may earn a commission at no extra cost to you. We only recommend products we would use ourselves, and product photos come from the retailer.